MS-T160 Advanced Use and Development

Update history
Date Version Author Update content
2026-11-18 v0.1 Sipeed
  • Initial release covering device settings, firmware update, multi-device subnet, custom web page, HTTP API and data format
  • {'Custom web page': 'how to get the source, embed all resources, and edit with AI help'}

Advanced Use and Development

This page has two parts:

  • Device settings: check the firmware version, update firmware, use several devices on one computer and replace the web page. Read these when you need them.
  • HTTP API: every piece of T160 data is available over HTTP, for your own programs, temperature logging or system integration.

Device Settings

In portrait, expand the Device settings & firmware panel at the bottom of the T160 web page. In landscape, tap the settings button in the left bar.

Check the Firmware Version

The Firmware update section of the panel shows the current version and build, for example Version x.y.z · build .... Include this line when you report a problem.

Update the Firmware

Firmware updates happen entirely in the web page. No computer tools are needed.

  1. Download the new T160 firmware file (.bin). Download link: coming soon.
  2. Open the T160 web page and expand the Device settings & firmware panel.
  3. In the Firmware update section, choose the .bin file, tap Install update and confirm.
  4. Wait for "Update complete. Device is restarting…".
  5. A few seconds later the page reconnects to the image. Check that the panel shows the new version.

⚠️ While the firmware is being written, do not unplug the T160, close the page or let the phone lock. The enclosure is sealed and has no reachable recovery button, so an interrupted update can leave the device unusable. Use a phone or computer with enough battery.

An update replaces only the program. The temperature calibration data on the device is kept, so no recalibration is needed.

Use Several Devices on One Computer (Subnet)

Every T160 uses the same address, 192.168.17.1, by default. Only when you plug two or more into one computer do they need different subnets to avoid conflicts. With a single T160 on a phone, change nothing.

  1. Plug in one T160 only, open its page and expand the Device settings & firmware panel.
  2. Under Multi-device subnet, enter a number from 1 to 254, for example 18, and tap Save & restart.
  3. After the restart the address becomes 192.168.18.1. Open it in the browser and check that the image appears.
  4. Repeat with the next T160, using a different number.

⚠️ Remember the new address. If you forget it, look up the IP of this USB network adapter on the computer. If it is 192.168.N.x, the device is at 192.168.N.1.

Customize the Web Page

You can replace the built-in page with your own HTML file:

  1. In the Custom web appearance section of the panel, choose an .html file and tap Upload & apply.
  2. Reload the page to see your design.

No web experience? Let an AI do the editing: give it the built-in page, describe what you want, and upload the result. For the steps and rules you can paste straight into the AI, see AI Integration: Let AI Edit the Web Page.

Keep these points in mind:

  • The built-in page is a single HTML file with no build step. Download its source with curl http://192.168.17.1/builtin -o t160.html, or open /builtin in a browser and view the page source, then edit the style, layout and text.
  • Keep the image elements <canvas id="view"> and #overlay, plus the code that reads /frame.temp8 or /stream.temp8. Super resolution keeps using the built-in /assets/sr-fast.wasm, /assets/sr-fast-simd.wasm and /assets/sr-fast.bin.
  • Embed every resource: inline SVG for icons and data URIs for images, with no CDN scripts, web fonts or remote images. An Android phone in airplane mode has no internet, so external resources would not load. A single file can be up to 124 KiB; the built-in page is about 84 KB.
  • A custom page stays through restarts and firmware updates. If it misbehaves after an update, redo your changes on the new built-in page.
  • If the custom page breaks, open http://192.168.17.1/builtin; the built-in page always works there. Tap Restore built-in page in the panel to delete the custom page.

HTTP API

The T160 runs an HTTP server on its USB network adapter, at the same address as the web page: http://192.168.17.1 by default, port 80. No login is needed, and only the phone or computer connected over USB can reach it.

In short: use /api/v1/thermal for temperatures and /frame.temp8 for a full temperature image.

Endpoints

Method and path Purpose
GET /api/v1/device Device info: model, serial, firmware, supported formats and capabilities
GET /api/v1/thermal Center, minimum and maximum temperatures of the current frame, with coordinates
GET /frame.temp8 One 160 × 120 8-bit temperature image followed by 120 bytes of metadata
GET /stream.temp8 Continuous temperature images; serves one connection at a time
GET /frame.adc16 One frame of unprocessed 14-bit raw data, for research and production tests
GET /api/v1/measurement Measurement parameters (read only); emissivity is fixed at 0.95
GET /api/v1/network Current subnet setting
PUT /api/v1/network Change the subnet; the device restarts afterwards
GET /api/v1/ota/status Firmware update status
POST /api/v1/ota Upload a .bin firmware
GET/POST/DELETE /api/v1/web Read, upload or delete the custom web page

Read Temperatures

curl http://192.168.17.1/api/v1/thermal

Example response:

{
  "frame_number": 18342,
  "timestamp_ms": 733600,
  "valid": true,
  "center":  {"celsius": 29.50, "x": 80,  "y": 60},
  "minimum": {"celsius": 8.20,  "x": 41,  "y": 97},
  "maximum": {"celsius": 33.70, "x": 132, "y": 21},
  "measurement_config_id": 0
}
  • celsius is in degrees Celsius. x and y are coordinates in the 160 × 120 native image; see Coordinates and image orientation.
  • valid is false right after start-up, before the first frame. Read again after 1 to 2 seconds.

Read Device Info

curl http://192.168.17.1/api/v1/device

The response is long. The most useful fields are:

  • device.model: always T160 for this product; device.firmware: the firmware version.
  • sensor.native_width and sensor.native_height: the native 160 × 120 resolution.
  • formats: the supported image formats and their paths. Read this first in your code instead of hard-coding the resolution.
  • network.device_ip: the current device address.

Temperature Image Format (temp8)

/frame.temp8 returns one fixed-length record of 19320 bytes:

[19200 bytes of pixels][120 bytes of metadata]
  • Pixels: 160 × 120 bytes, one byte per pixel, in native orientation, row by row from the top-left corner. Pixel (x, y) is at offset y × 160 + x.
  • Temperature: °C = pixel × temperature_scale + temperature_offset. Pixels above quant_max are invalid.
  • Precision: each frame maps a range picked automatically by the device onto 0 to quant_max (currently 254). One step equals temperature_scale, so a scene with a wider temperature spread gets coarser steps. For the maximum, minimum and center, use the values in the metadata or /api/v1/thermal; they are not quantized.
  • If temperature_scale is NaN, the frame has no valid temperature mapping (for example a perfectly uniform scene). Read the next frame.

The metadata starts with the ASCII magic SITHMETA. All multi-byte fields are little-endian. The most useful fields:

Offset Size Type Field Meaning
0 8 char[8] magic Always SITHMETA
16 4 u32 frame_number Frame number
24 4 u32 timestamp_ms Milliseconds since start-up
36 6 u16 × 3 width, height, stride_bytes 160, 120, 160
47 1 u8 quant_max Largest valid pixel value
48 8 f32 × 2 temperature_scale, temperature_offset Pixel-to-temperature coefficients
56 12 f32 × 3 Center, minimum, maximum temperature In °C
68 12 u16 × 6 x and y of the center, minimum and maximum Native coordinates
116 4 u32 meta_crc32 CRC-32 of the first 116 bytes (same as zlib.crc32)

The response headers also carry the sizes, for example X-Sipeed-Width: 160 and X-Sipeed-Record-Bytes: 19320, which you can use for checks.

Continuous Stream (stream.temp8)

/stream.temp8 keeps sending records like the one above, back to back, with no separator and no Content-Length. Cut every 19320 bytes and check the magic and CRC of each record.

⚠️ Only one stream runs at a time: a new connection drops the old one. The T160 web page itself uses this stream, so close the page before reading the stream from a program, or the two will keep taking the image from each other. For occasional reads, use /frame.temp8 or /api/v1/thermal, which have no such limit.

Coordinates and Image Orientation

All API coordinates use the 160 × 120 native landscape image with the origin at the top-left. For a phone held upright, the T160 web page rotates the image 90° counterclockwise into a 360 × 480 portrait view. Turning the phone or rotating by hand changes the displayed orientation. Convert by the orientation in use when you match API coordinates to a screenshot of the page.

Python Example

This program uses only the Python standard library. It reads one temperature image, checks it, and prints the center temperature and the hottest pixel.

import struct
import urllib.request
import zlib

BASE = "http://192.168.17.1"

record = urllib.request.urlopen(BASE + "/frame.temp8", timeout=5).read()
pixels, meta = record[:-120], record[-120:]

assert meta[:8] == b"SITHMETA", "not a T160 frame"
assert zlib.crc32(meta[:116]) == struct.unpack_from("<I", meta, 116)[0], "CRC mismatch"

width, height, stride = struct.unpack_from("<HHH", meta, 36)
quant_max = meta[47]
scale, offset = struct.unpack_from("<ff", meta, 48)


def temperature(x, y):
    value = pixels[y * stride + x]
    return None if value > quant_max else value * scale + offset


print("Center: %.1f C" % temperature(width // 2, height // 2))
value, x, y = max((pixels[y * stride + x], x, y)
                  for y in range(height) for x in range(width)
                  if pixels[y * stride + x] <= quant_max)
print("Hottest pixel: (%d, %d) %.1f C" % (x, y, value * scale + offset))

Before running it, make sure the computer is connected to the T160 and the browser can open http://192.168.17.1.

Write Operations

Writes such as changing the subnet, updating firmware or uploading a custom page must send the header X-Sipeed-Request: 1 and the correct Content-Type; otherwise the device returns 400. This stops ordinary web pages from changing the device without your knowledge.

Change the subnet (the device restarts about 1.5 seconds later at 192.168.18.1):

curl -X PUT http://192.168.17.1/api/v1/network \
  -H 'Content-Type: application/json' \
  -H 'X-Sipeed-Request: 1' \
  -d '{"segment": 18}'

Upload firmware (the same cautions as in Update the Firmware apply; do not unplug during the write):

curl -X POST http://192.168.17.1/api/v1/ota \
  -H 'Content-Type: application/octet-stream' \
  -H 'X-Sipeed-Request: 1' \
  --data-binary @t160.bin
curl http://192.168.17.1/api/v1/ota/status

Upload or delete a custom page (GET /api/v1/web shows whether one is in use):

curl -X POST http://192.168.17.1/api/v1/web \
  -H 'Content-Type: text/html' \
  -H 'X-Sipeed-Request: 1' \
  --data-binary @t160.html
curl -X DELETE http://192.168.17.1/api/v1/web -H 'X-Sipeed-Request: 1'

Common Status Codes

Code Meaning What to do
200 Success —
202 Write accepted, for example the device is about to restart Reconnect to the new address after a few seconds
400 Malformed request, or X-Sipeed-Request: 1 is missing Check the headers and body
404 No such endpoint Check the path
409 The operation is not allowed in the current state Try again later
503 No image available yet Wait for the Retry-After header and retry

Next Steps

  • To let AI tools read temperatures and images directly, or edit the web page for you, see AI Integration.